{"id":6304,"date":"2026-09-01T11:45:59","date_gmt":"2026-09-01T03:45:59","guid":{"rendered":"https:\/\/londianglobal.com\/?p=6304"},"modified":"2026-09-01T11:45:59","modified_gmt":"2026-09-01T03:45:59","slug":"direct-connected-meter-oem","status":"publish","type":"post","link":"https:\/\/londianglobal.com\/cs\/blog\/direct-connected-meter-oem","title":{"rendered":"Direct Connected Meter OEM"},"content":{"rendered":"<h1><span class=\"\">Direct Connected Meter OEM: The Complete Guide to Whole Current Meter Solutions<\/span><\/h1>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">The global energy landscape evolves rapidly. Accurate electricity metering underpins utility revenue protection and grid management. Among available metering technologies, the\u00a0<\/span><strong><span class=\"\">direct connected meter<\/span><\/strong><span class=\"\">\u2014or whole current meter\u2014remains the most prevalent solution for residential, commercial, and light industrial applications. Smart grid integration and advanced metering infrastructure (AMI) drive growing demand for Original Equipment Manufacturer (OEM) partnerships. This comprehensive guide explores technical nuances, strategic benefits, and manufacturing excellence behind direct connected meter OEM solutions.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4558\" src=\"https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.13-Fully-automatic-test-line.webp\" alt=\"\" width=\"2275\" height=\"1279\" srcset=\"https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.13-Fully-automatic-test-line.webp 2275w, https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.13-Fully-automatic-test-line-300x169.webp 300w, https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.13-Fully-automatic-test-line-1030x579.webp 1030w, https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.13-Fully-automatic-test-line-768x432.webp 768w, https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.13-Fully-automatic-test-line-1536x864.webp 1536w, https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.13-Fully-automatic-test-line-2048x1151.webp 2048w, https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.13-Fully-automatic-test-line-18x10.webp 18w, https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.13-Fully-automatic-test-line-800x450.webp 800w\" sizes=\"auto, (max-width: 2275px) 100vw, 2275px\" \/><\/p>\n<h2><span class=\"\">What is a <a href=\"https:\/\/londianglobal.com\/cs\/\">Direct Connected Meter<\/a>?<\/span><\/h2>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">A direct connected meter carries the full load current directly through the device itself. Unlike transformer-operated (CT) meters, these devices require no external current transformers to scale down high currents. Internal current-carrying conductors handle the circuit&#8217;s entire current capacity. This design makes them the preferred choice for applications with typical current ranges from 10A to 100A, though some industrial variants can reach up to 200A.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Direct-connected meters are available in both single-phase and polyphase configurations. These devices accommodate standard voltage references including 120V, 230V, 240V, and 400V depending on regional requirements. The &#8220;whole current&#8221; design philosophy offers inherent advantages: simplified installation, reduced overall system cost, lower burden errors, and enhanced reliability in low-power applications. These characteristics have cemented their position as the standard for over 328 million annual meter shipments globally.<\/span><\/p>\n<h2><span class=\"\">The Strategic Advantage of OEM Partnerships<\/span><\/h2>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">For utilities, system integrators, and distribution network operators, choosing the right OEM partner for direct connected meters represents a strategic decision with far-reaching implications. Londian, a premier whole current meter manufacturer with nearly three decades of expertise, exemplifies the capabilities that modern OEM partnerships must deliver.<\/span><\/p>\n<h3><span class=\"\">OEM vs. ODM: Understanding the Distinction<\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Procurement managers and engineering teams must clearly understand the difference between OEM and ODM. In an OEM arrangement, the customer provides the complete design\u2014including bill of materials, PCB layouts, and firmware\u2014while the manufacturer produces to specification. This approach offers high customization but typically requires longer development timelines (12\u201318 months) and higher non-recurring engineering fees.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Conversely, ODM partnerships leverage the manufacturer&#8217;s existing, field-proven reference designs. Customers can modify enclosure color, branding, display languages, and communication protocols while benefiting from shorter time-to-market (3\u20136 months) and lower development costs. Londian maintains over 50 reference designs covering single-phase, three-phase, and prepayment whole current meters, enabling rapid customization without sacrificing quality.<\/span><\/p>\n<h2><span class=\"\">Technical Specifications and Standards Compliance<\/span><\/h2>\n<h3><span class=\"\">Core Performance Parameters<\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Direct connected meters from leading OEMs adhere to rigorous international standards that ensure interoperability and accuracy. Key certifications include IEC 62052-11, IEC 62053-21, and IEC 62053-23, which cover alternating current static meters for active and reactive energy measurement. For the European market, MID Certification (Measuring Instruments Directive) remains essential, while North American deployments require compliance with ANSI C12.1\/C12.20.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Londian&#8217;s direct connected meters achieve Class 1.0 and Class 0.5S accuracy ratings. These ratings exceed the regulatory minimum requirement of \u00b11.5% error tolerance. Advanced large-scale integrated circuits and Surface Mount Technology (SMT) manufacturing processes enable this precision. These processes ensure excellent linearity and stable temperature characteristics across the entire operating range.<\/span><\/p>\n<h3><span class=\"\">Communication and Smart Grid Readiness<\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Modern direct connected meters must seamlessly integrate with utility data networks. Leading OEM solutions offer multiple communication interfaces. These include RS485 for wired data acquisition, infrared optical ports for local configuration, and plug-and-play modules supporting PLC (Power Line Communication), RF mesh, 2G\/3G\/4G cellular, and emerging LoRaWAN and NB-IoT technologies. AMI interoperability design enables remote firmware upgrades and real-time data transmission. This transforms meters from passive measurement devices into active grid management nodes.<\/span><\/p>\n<h2><span class=\"\">Manufacturing Excellence and Quality Assurance<\/span><\/h2>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">The reliability of direct connected meters depends critically on manufacturing quality. Londian&#8217;s state-of-the-art facility spans over 50,000 square meters and operates under Industry 4.0 principles. Fully automated SMT lines with AI-driven optical inspection systems maintain defect rates below 0.1%. Every meter undergoes 100% burn-in testing and 72-hour stress cycles. These tests cover extreme temperatures from -40\u00b0C to +70\u00b0C, ensuring reliable operation across diverse environments.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">The Manufacturing Execution System (MES) provides complete traceability. This system logs every component against a unique serial number. This comprehensive traceability enables rapid identification of any quality issues. It also supports auditability requirements. With an annual production capacity exceeding 11 million single-phase meters and 2.1 million three-phase meters, Londian ensures supply chain resilience and rapid lead times even during global component shortages.<\/span><\/p>\n<h2><span class=\"\">Z\u00e1v\u011br<\/span><\/h2>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Direct connected meter OEM solutions represent the convergence of proven metrology technology and strategic manufacturing partnerships. The global energy meter market continues its trajectory toward US$14.95 billion by 2032. Stakeholders who partner with established manufacturers offering comprehensive customization capabilities, international standards compliance, and robust quality assurance will be best positioned for success. Whether through full OEM customization or ODM platform adaptation, the right direct connected meter solution delivers reliable measurement, seamless grid integration, and lasting value.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Direct Connected Meter OEM: The Complete Guide to Whole Current Meter Solutions The global energy landscape evolves rapidly. Accurate electricity metering underpins utility revenue protection and grid management. Among available metering technologies, the\u00a0direct connected meter\u2014or whole current meter\u2014remains the most prevalent solution for residential, commercial, and light industrial applications. Smart grid integration and advanced metering&#8230;<\/p>","protected":false},"author":3,"featured_media":4557,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-6304","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Direct Connected Meter OEM - Londian<\/title>\n<meta name=\"description\" content=\"Direct Connected Meter OEM solutions from Londian. Learn about whole current meter technology, international standards\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/londianglobal.com\/cs\/blog\/direct-connected-meter-oem\" \/>\n<meta property=\"og:locale\" content=\"cs_CZ\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Direct Connected Meter OEM - Londian\" \/>\n<meta property=\"og:description\" content=\"Direct Connected Meter OEM solutions from Londian. Learn about whole current meter technology, international standards\" \/>\n<meta property=\"og:url\" content=\"https:\/\/londianglobal.com\/cs\/blog\/direct-connected-meter-oem\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-01T03:45:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.12-Fully-automatic-test-line-scaled.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1440\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Tina\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Rocky\" \/>\n<meta name=\"twitter:label1\" content=\"Napsal(a)\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tina\" \/>\n\t<meta name=\"twitter:label2\" content=\"Odhadovan\u00e1 doba \u010dten\u00ed\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem\"},\"author\":{\"name\":\"Tina\",\"@id\":\"https:\\\/\\\/londianglobal.com\\\/#\\\/schema\\\/person\\\/691da96ccdd2a899702e96be4c0b892e\"},\"headline\":\"Direct Connected Meter OEM\",\"datePublished\":\"2026-09-01T03:45:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem\"},\"wordCount\":790,\"image\":{\"@id\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/londianglobal.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/2.12-Fully-automatic-test-line-scaled.webp\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"cs\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem\",\"url\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem\",\"name\":\"Direct Connected Meter OEM - Londian\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/londianglobal.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/londianglobal.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/2.12-Fully-automatic-test-line-scaled.webp\",\"datePublished\":\"2026-09-01T03:45:59+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/londianglobal.com\\\/#\\\/schema\\\/person\\\/691da96ccdd2a899702e96be4c0b892e\"},\"description\":\"Direct Connected Meter OEM solutions from Londian. Learn about whole current meter technology, international standards\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem#breadcrumb\"},\"inLanguage\":\"cs\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem#primaryimage\",\"url\":\"https:\\\/\\\/londianglobal.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/2.12-Fully-automatic-test-line-scaled.webp\",\"contentUrl\":\"https:\\\/\\\/londianglobal.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/2.12-Fully-automatic-test-line-scaled.webp\",\"width\":2560,\"height\":1440},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/direct-connected-meter-oem#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/londianglobal.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/londianglobal.com\\\/blog\\\/blog\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Direct Connected Meter OEM\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/londianglobal.com\\\/#website\",\"url\":\"https:\\\/\\\/londianglobal.com\\\/\",\"name\":\"\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/londianglobal.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"cs\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/londianglobal.com\\\/#\\\/schema\\\/person\\\/691da96ccdd2a899702e96be4c0b892e\",\"name\":\"Tina\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g\",\"caption\":\"Tina\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/Rocky\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Direct Connected Meter OEM - Londian","description":"Direct Connected Meter OEM solutions from Londian. Learn about whole current meter technology, international standards","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/londianglobal.com\/cs\/blog\/direct-connected-meter-oem","og_locale":"cs_CZ","og_type":"article","og_title":"Direct Connected Meter OEM - Londian","og_description":"Direct Connected Meter OEM solutions from Londian. Learn about whole current meter technology, international standards","og_url":"https:\/\/londianglobal.com\/cs\/blog\/direct-connected-meter-oem","article_published_time":"2026-09-01T03:45:59+00:00","og_image":[{"width":2560,"height":1440,"url":"https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.12-Fully-automatic-test-line-scaled.webp","type":"image\/webp"}],"author":"Tina","twitter_card":"summary_large_image","twitter_creator":"@Rocky","twitter_misc":{"Napsal(a)":"Tina","Odhadovan\u00e1 doba \u010dten\u00ed":"4 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem#article","isPartOf":{"@id":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem"},"author":{"name":"Tina","@id":"https:\/\/londianglobal.com\/#\/schema\/person\/691da96ccdd2a899702e96be4c0b892e"},"headline":"Direct Connected Meter OEM","datePublished":"2026-09-01T03:45:59+00:00","mainEntityOfPage":{"@id":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem"},"wordCount":790,"image":{"@id":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem#primaryimage"},"thumbnailUrl":"https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.12-Fully-automatic-test-line-scaled.webp","articleSection":["Blog"],"inLanguage":"cs"},{"@type":"WebPage","@id":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem","url":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem","name":"Direct Connected Meter OEM - Londian","isPartOf":{"@id":"https:\/\/londianglobal.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem#primaryimage"},"image":{"@id":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem#primaryimage"},"thumbnailUrl":"https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.12-Fully-automatic-test-line-scaled.webp","datePublished":"2026-09-01T03:45:59+00:00","author":{"@id":"https:\/\/londianglobal.com\/#\/schema\/person\/691da96ccdd2a899702e96be4c0b892e"},"description":"Direct Connected Meter OEM solutions from Londian. Learn about whole current meter technology, international standards","breadcrumb":{"@id":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem#breadcrumb"},"inLanguage":"cs","potentialAction":[{"@type":"ReadAction","target":["https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem"]}]},{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem#primaryimage","url":"https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.12-Fully-automatic-test-line-scaled.webp","contentUrl":"https:\/\/londianglobal.com\/wp-content\/uploads\/2025\/07\/2.12-Fully-automatic-test-line-scaled.webp","width":2560,"height":1440},{"@type":"BreadcrumbList","@id":"https:\/\/londianglobal.com\/blog\/direct-connected-meter-oem#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/londianglobal.com\/"},{"@type":"ListItem","position":2,"name":"Blog","item":"https:\/\/londianglobal.com\/blog\/blog"},{"@type":"ListItem","position":3,"name":"Direct Connected Meter OEM"}]},{"@type":"WebSite","@id":"https:\/\/londianglobal.com\/#website","url":"https:\/\/londianglobal.com\/","name":"","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/londianglobal.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"cs"},{"@type":"Person","@id":"https:\/\/londianglobal.com\/#\/schema\/person\/691da96ccdd2a899702e96be4c0b892e","name":"Tina","image":{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/secure.gravatar.com\/avatar\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g","caption":"Tina"},"sameAs":["https:\/\/x.com\/Rocky"]}]}},"_links":{"self":[{"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/posts\/6304","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/comments?post=6304"}],"version-history":[{"count":1,"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/posts\/6304\/revisions"}],"predecessor-version":[{"id":6305,"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/posts\/6304\/revisions\/6305"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/media\/4557"}],"wp:attachment":[{"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/media?parent=6304"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/categories?post=6304"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/londianglobal.com\/cs\/wp-json\/wp\/v2\/tags?post=6304"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}